VFD made by Sumitomo. It can be used to create 3-phase from single phase electricity of a similar voltage, but must be derated by half when doing so. R and T must be wired with S left out, this is important because the control circuitry draws power from 2 of the 3 phases.
 
VFD made by Sumitomo. It can be used to create 3-phase from single phase electricity of a similar voltage, but must be derated by half when doing so. R and T must be wired with S left out, this is important because the control circuitry draws power from 2 of the 3 phases.
   −
== Factory Reset ==
+
== Model Numbers ==
 +
 
 +
* Page 26 (2-12 in the PDF) gives a table of model numbers and specifications
 +
* Page 130 (6-1 in the PDF) gives a table of model numbers and specifications
 +
 
 +
== Wiring Diagram ==
 +
 
 +
* Page 19 (2-6-1 in the PDF) shows the general wiring
 +
* Page 21 (2-7 in the PDF) gives a description of the terminals
 +
* Page 24 (2-10 in the PDF) shows the power terminal block pinout
 +
* Page 28 (2-14 in the PDF) shows the control terminal block pinout
 +
 
 +
== Dimensions ==
 +
 
 +
* Page 131 (6-2 in the PDF) gives the dimensional diagram
 +
 
 +
== Keypad ==
 +
 
 +
=== Operation ===
 +
 
 +
* Page 30 (3-1 in the PDF) explains how to use the keypad
 +
* Page 34 (4-1 in the PDF) shows a diagram of the keypad and explanation of how to use it
 +
 
 +
=== Factory Reset ===
    
[https://s3.amazonaws.com/Icarus/DOCUMENTS/SumitomoCorporation_Manuals_2036.pdf#page=16 Page 16] of the pocket guide details how to factory reset the parameters.
 
[https://s3.amazonaws.com/Icarus/DOCUMENTS/SumitomoCorporation_Manuals_2036.pdf#page=16 Page 16] of the pocket guide details how to factory reset the parameters.
 +
 +
== Parameters ==
 +
 +
* Page 38 (4-5 in the PDF) gives a table of the parameters
    