3,996 bytes added
, 17:12, 10 January 2021
== Overview ==
Variable frequency drives (VFDs) made by KEB.
== Model Numbers ==
In the 00.F5.GEA-K230 manual:
* [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=21 Page 21] shows the model number scheme.
In the 00.F5.LUB-K140 manual:
* [https://s3.amazonaws.com/Icarus/DOCUMENTS/KEB_Manuals_1675.pdf#page=8 Page 8] shows the model number scheme.
== Wiring Diagram ==
In the 00.F5.GEA-K230 manual:
* [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=32 Page 32] shows the X2A terminal strip pinout.
* [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=313 Page 313] shows the DE9 pinout for both the TTL interface on the control board and the RS-232 on the operator panel.
== Software ==
COMBIVIS Studio 6
{| class="wikitable"
! Filename
! Size
! MD5
! SHA1
|-
| Setup_COMBIVIS_studio_6.exe
| 1,600,809,016 bytes
| a1ae3829a336dc1353c17bcca0e8fc9e
| f3daa92a3c9b1f0a4bed9eeb0d90e83b12c389a8
|}
[https://www.keb.co.uk/index.php?eID=tx_securedownloads&u=0&file=fileadmin/media/Software/combivis6/Setup_COMBIVIS_studio_6.exe&t=1610385988&hash=62a73c21bfad82337ae0278be53b87a4fdfa0253 Setup_COMBIVIS_studio_6.exe] (direct link, may not work...)
[https://www.keb.co.uk/index.php?eID=tx_securedownloads&u=0&file=/fileadmin/media/Software/combivis6/Setup_COMBIVIS_studio_6.exe&t=1610386097&hash=bcf2b455610de4956f368b3149bafcba1d85ec90 Setup_COMBIVIS_studio_6.exe] (different t and hash)
[https://www.keb.co.uk/control-automation/tools/development-environment/combivis-studio-6 COMBIVIS studio 6 | KEB Automation with Drive]
[https://www.keb.co.uk/drive-technology/tools/engineering-tool-combivis-6 Software tool COMBIVIS for mdular Drive Controller | KEB Automation with Drive]
[https://www.kebamerica.com/products/combivis-6-drive-software/ COMBIVIS 6 - VFD Software | Products | KEB]
== Modbus control ==
TODO
== Replacement Parts ==
=== Operator Panel ===
* 00.F5.060-2000 "Interface-Operator" on [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=315 Page 314]
* 00.F5.060-3000 "Profibus-DP-Operator" on [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=315 Page 315]
* 00.F5.060-4000 "InterBus Operator" on [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=316 Page 316]
* 00.F5.060-5000 "CanOpen Operator" on [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=317 Page 317]
* 00.F5.060-6000 "Sercos Operator" on [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=318 Page 318]
=== RS-232 Cable ===
* 00.58.025-001D "RS232-Cable PC / Operator" on [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=313 Page 313]
=== TTL Cable ===
* 00.F5.0C0-0001 "HSP5-Cable PC / Control Board" on [http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf#page=313 Page 313]
== Online Resources ==
[https://www.keb.co.uk/drive-technology/drive-controller-for-your-drive-tasks/application-drive-combivert-f5 KEB COMBIVERT F5 Modular Drive | KEB Automation with Drive]
[https://www.kebamerica.com/products/f5-inverter/ F5 Inverter | Products | KEB]
[https://www.keb.co.uk/drive-technology/drive-controller-for-your-drive-tasks/application-drive-combivert-f5/combivert-f5-fieldbus-operator COMBIVERT F5 Fieldbus Operator | KEB Automation with Drive]
[http://www.keb.com.tw/Files/Other/PDF/keb/combivert/ct_dr_000000052f5_en.pdf KEB COMBIVERT F5 Modular Drives Catalog]
[http://sigi-elect.si/sites/default/files/doc_tree/M_F5_B_G_rus.pdf KED COMBIVERT F5-BASIC/GENERAL 2.3 (Part. No.: 00.F5.GEA-K230, 06/2002)]
[https://s3.amazonaws.com/Icarus/DOCUMENTS/KEB%5FManuals%5F1675.pdf KEB COMBIVERT F5 Instruction Manual (00.F5.LUB-K140)]
[https://claddaghelectronics.com/attachment.php?id_attachment=11 KEB COMBIVERT F5 Instruction Manual (00.F5.LUB-K140)] (alternate link)
https://gnnvietnam.com/upload/pdf/09%5B1%5D.F5.B1B-2B00_KEB%20Vietnam.pdf#page=4 (alternate catalog)