| == Modbus control == | | == Modbus control == |
| | | |
− | DZB300 manual applies to DZB312 for Modbus information. | + | === VFD parameters === |
| + | |
| + | In the DZB312 series manual: |
| + | |
| + | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (17 in the PDF) gives the parameter list |
| + | |
| + | Here are the ones relevant for Modbus control: |
| + | |
| + | {| class="wikitable" |
| + | ! Function Code |
| + | ! Serial No. |
| + | ! Default Value |
| + | ! Required Value |
| + | ! Description |
| + | |- |
| + | | F0.01 |
| + | | 1 |
| + | | 1: terminal |
| + | | 2: RS-485 |
| + | | run command source |
| + | |- |
| + | | F0.03 |
| + | | 3 |
| + | | 1: AVI |
| + | | 6: RS-485 |
| + | | frequency command source |
| + | |- |
| + | | F3.03 |
| + | | 81 |
| + | | 0: only keypad |
| + | | 2: keypad and RS-485 |
| + | | stop function sources |
| + | |- |
| + | | F4.11 |
| + | | 108 |
| + | | 0 |
| + | | ? |
| + | | fault automatic reset number |
| + | |- |
| + | | F4.18 |
| + | | 115 |
| + | | 0: keypad (F4.19) |
| + | | 3: RS-485 |
| + | | PID setpoint source |
| + | |- |
| + | | F4.20 |
| + | | 117 |
| + | | 0: reserved |
| + | | 3: RS-485 |
| + | | PID feedback source |
| + | |- |
| + | | F6.00 |
| + | | 142 |
| + | | 1 |
| + | | |
| + | | RS-485 Modbus slave address |
| + | |- |
| + | | F6.01 |
| + | | 143 |
| + | | 3: 9,600 bps |
| + | | |
| + | | RS-485 Modbus baudrate |
| + | |- |
| + | | F6.02 |
| + | | 144 |
| + | | 0: N, 8, 1 |
| + | | |
| + | | RS-485 Modbus parity/data-width/stop-bits |
| + | |- |
| + | | F6.03 |
| + | | 145 |
| + | | 5 |
| + | | |
| + | | RS-485 Modbus response delay (ms) |
| + | |- |
| + | | F6.04 |
| + | | 146 |
| + | | 0.0 (invalid) |
| + | | 2.0 (2 seconds) |
| + | | RS-485 Modbus timeout (s) |
| + | |- |
| + | | F6.05 |
| + | | 147 |
| + | | 1: continue without alarm |
| + | | 2: stop with alarm (only when in RS-485 mode) |
| + | | RS-485 Modbus error handling |
| + | |- |
| + | | F6.06 |
| + | | 148 |
| + | | 0: respond to writes |
| + | | 0: respond to writes |
| + | | RS-485 Modbus write response |
| + | |} |
| + | |
| + | === Modbus registers === |
| + | |
| + | In the DZB300 series manual (which also applies to DZB312 series): |
| + | |
| + | * [http://www.chinafolinn.com/uploads/image/20200602/5ed6233f8b4eb.pdf#page=49 Page 49] (91 in the PDF) describes the Modbus protocol (should be standards compliant) |
| + | * [http://www.chinafolinn.com/uploads/image/20200602/5ed6233f8b4eb.pdf#page=53 Page 53] (100 in the PDF) has the register address map |
| | | |