Sumitomo HF-430 Series VFDs
Overview
VFD made by Sumitomo. It can be used to create 3-phase from single phase electricity of a similar voltage, but must be derated by half when doing so. R and T must be wired with S left out, this is important because the control circuitry draws power from 2 of the 3 phases.
Model Numbers
- Page 26 (2-12 in the PDF) gives a table of model numbers and specifications
- Page 130 (6-1 in the PDF) gives a table of model numbers and specifications
Wiring Diagram
- Page 19 (2-6-1 in the PDF) shows the general wiring
- Page 21 (2-7 in the PDF) gives a description of the terminals
- Page 24 (2-10 in the PDF) shows the power terminal block pinout
- Page 28 (2-14 in the PDF) shows the control terminal block pinout
Dimensions
- Page 131 (6-2 in the PDF) gives the dimensional diagram
Keypad
Operation
- Page 30 (3-1 in the PDF) explains how to use the keypad
- Page 34 (4-1 in the PDF) shows a diagram of the keypad and explanation of how to use it
Factory Reset
Page 16 of the pocket guide details how to factory reset the parameters.
Parameters
- Page 38 (4-5 in the PDF) gives a table of the parameters
Online Resources
Sumitomo HF-430 Series Operating and Maintenance Manual D1401E-3.2 (2010.06)
Sumitomo HF-430 Series Operating and Maintenance Manual DM1401E-2.10 (2011.04) (scanned)
Sumitomo HF430 AC Drive Pocket Guide
Sumitomo Speed Reducers & Gearmotors - AC Inverter HF430 (Wayback Machine)
HF430 AC FLUX VECTOR DRIVE (Wayback Machine)