ABB ACS550 VFD
Overview
VFD made by ABB, has an option for encoder feedback for closed loop spindle speed.
Software
Page 3 shows the pin mapping from the DB9 to the RJ45.
Page 11 mentions DriveWindow Light 2
Modbus Control
mbpoll
There is an open source utility that can speak Modbus over a serial port (or USB to serial) that has an RS-485 adapter attached. It's called mbpoll:
https://github.com/epsilonrt/mbpoll
mbpoll
commands to interact with the VFD:
# to turn the spindle on ./mbpoll /dev/ttyUSB0 6 -b 9600 -s 1 -P none -a 1 -r 1 -t 4 sleep 0.1 ./mbpoll /dev/ttyUSB0 7 -b 9600 -s 1 -P none -a 1 -r 1 -t 4 ./mbpoll /dev/ttyUSB0 15 -b 9600 -s 1 -P none -a 1 -r 1 -t 4 ./mbpoll /dev/ttyUSB0 47 -b 9600 -s 1 -P none -a 1 -r 1 -t 4 ./mbpoll /dev/ttyUSB0 111 -b 9600 -s 1 -P none -a 1 -r 1 -t 4 # to turn the spindle off ./mbpoll /dev/ttyUSB0 6 -b 9600 -s 1 -P none -a 1 -r 1 -t 4 # to reset a fault (needs to be tested) ./mbpoll /dev/ttyUSB0 1 -b 9600 -s 1 -P none -a 1 -r 8 -t 0 # monitor output frequency (displays Hz * 10) ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -r 103 -t 4 # monitor output current (displays A * 10) ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -r 104 -t 4 # monitor output power (displays kW * 10) ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -r 106 -t 4 # monitor output voltage (displays V) ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -r 109 -t 4
Replacement Parts
OPCA-01
RJ45 to DE9 adapter used to program the VFD using PC based software:
$22.50 + $9.90 -- ASEA BROWN BOVERI OPCA-01 / OPCA01 (RQANS2)
OTAC-01
Pulse Encoder Interface
Online Resources
ACS550 - General purpose drives - (Low voltage AC) | ABB
ABB ACS550 User’s Manual Rev H 2014-07-04
ACH550-01/02/U1/U2 Embedded Fieldbus Control