Difference between revisions of "Folinn H1 Series VFDs"
(added MODBUS register address scheme notes) |
(updated PDF links to use wiki copy of PDF) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 19: | Line 19: | ||
== Model Numbers == | == Model Numbers == | ||
− | * [https://www. | + | * [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf#page=6 Page 6] (7 in the PDF) shows the model number scheme |
== Wiring Diagram == | == Wiring Diagram == | ||
− | * [https://www. | + | * [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf#page=7 Page 7] (10 in the PDF) shows the power wiring |
− | * [https://www. | + | * [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf#page=67 Page 67] (129 in the PDF) shows the H0101 interface panel screw terminal / RJ45 pinout |
− | * [https://www. | + | * [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf#page=68 Page 68] (132 in the PDF) shows the H0110 interface panel screw terminal / RJ45 pinout |
− | * [https://www. | + | * [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf#page=72 Page 72] (139 in the PDF) shows the H0100 interface panel screw terminal pinout |
− | * [https://www. | + | * [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf#page=73 Page 73] (142 in the PDF) shows the H0200 interface panel screw / RJ45 / D-Sub? terminal pinout |
− | * [https://www. | + | * [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf#page=76 Page 76] (147 in the PDF) shows the H0201 interface panel screw / RJ45 / D-Sub? terminal pinout |
NOTE: they claim that pins 1&2 on the RJ45 are RS-485+/-, but in reality it's reversed and pins 8&7 are RS-485+/- and pins 2&4 are GND. | NOTE: they claim that pins 1&2 on the RJ45 are RS-485+/-, but in reality it's reversed and pins 8&7 are RS-485+/- and pins 2&4 are GND. | ||
Line 34: | Line 34: | ||
== Dimensions == | == Dimensions == | ||
− | * [https://www. | + | * [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf#page=65 Page 65] (126 in the PDF) show a table of the dimensions |
+ | |||
+ | == Parameters == | ||
+ | |||
+ | {| class="wikitable" | ||
+ | ! Parameter No. | ||
+ | ! Default Value | ||
+ | ! Range | ||
+ | ! Description | ||
+ | |- | ||
+ | | P02.18 | ||
+ | | 50.000 Hz | ||
+ | | 0.000 - 99999.000 Hz | ||
+ | | Maximum setting value | ||
+ | |- | ||
+ | | P02.19 | ||
+ | | 0.000 Hz | ||
+ | | 0.000 - 99999.000 Hz | ||
+ | | Minimum setting value | ||
+ | |- | ||
+ | | P02.50 | ||
+ | | | ||
+ | | 0.050 - 3600.000 s | ||
+ | | Acceleration time 0 | ||
+ | |- | ||
+ | | P02.70 | ||
+ | | | ||
+ | | 0.050 - 3600.000 s | ||
+ | | Deceleration time 0 | ||
+ | |- | ||
+ | | P05.08 | ||
+ | | 55.000 Hz | ||
+ | | -1020.000 - 1020.000 Hz | ||
+ | | Motor upper frequency limit | ||
+ | |- | ||
+ | | P06.00 | ||
+ | | | ||
+ | | 0: off<br/>1: complete<br/>2: simple | ||
+ | | Motor parameter self-learning | ||
+ | |- | ||
+ | | P06.10 | ||
+ | | 0: asynchronous | ||
+ | | 0: asynchronous<br/>1: surface mount permanent magnet synchronous<br/>2: salient pole permanent magnet synchronous<br/>4: single-phase motor | ||
+ | | Motor type | ||
+ | |- | ||
+ | | P06.05 | ||
+ | | | ||
+ | | 2-16 kHz | ||
+ | | Carrier frequency | ||
+ | |- | ||
+ | | P06.11 | ||
+ | | | ||
+ | | 0.000 - 100000.000 kW | ||
+ | | Motor rated power | ||
+ | |- | ||
+ | | P06.12 | ||
+ | | | ||
+ | | 0 - 1000 V | ||
+ | | Motor rated voltage | ||
+ | |- | ||
+ | | P06.13 | ||
+ | | | ||
+ | | 1 - 3000 Hz | ||
+ | | Motor rated frequency | ||
+ | |- | ||
+ | | P06.14 | ||
+ | | | ||
+ | | 0.00 - 1000.00 A | ||
+ | | Motor rated current | ||
+ | |- | ||
+ | | P06.15 | ||
+ | | | ||
+ | | 10 - 65535 RPM | ||
+ | | Motor rated speed | ||
+ | |- | ||
+ | | P06.16 | ||
+ | | | ||
+ | | 0.00 - 1.00 (ratio) | ||
+ | | Motor power factor | ||
+ | |- | ||
+ | | P06.17 | ||
+ | | | ||
+ | | 2 - 100 poles (not pairs) | ||
+ | | Motor pole count | ||
+ | |- | ||
+ | | P06.18 | ||
+ | | | ||
+ | | 0.1 - 10000.0 Nm | ||
+ | | Motor rated torque | ||
+ | |- | ||
+ | | P06.19 | ||
+ | | | ||
+ | | 0.00 - 1000.00 A | ||
+ | | Motor no-load current | ||
+ | |- | ||
+ | | P06.20 | ||
+ | | | ||
+ | | 1.000 - 10000.000 mV/RPM | ||
+ | | PM motor back EMF/rev | ||
+ | |- | ||
+ | | P06.40 | ||
+ | | | ||
+ | | 0.000 - 99.990 ohms | ||
+ | | Stator impedance | ||
+ | |- | ||
+ | | P06.41 | ||
+ | | | ||
+ | | 0.000 - 99.990 ohms | ||
+ | | Rotor impedance | ||
+ | |- | ||
+ | | P06.42 | ||
+ | | | ||
+ | | 0.000 - 999.990 mH | ||
+ | | Stator leakage reactance | ||
+ | |- | ||
+ | | P06.44 | ||
+ | | | ||
+ | | 0.00 - 999.90 mH | ||
+ | | Motor main reactance | ||
+ | |} | ||
== Modbus control == | == Modbus control == | ||
Line 324: | Line 443: | ||
=== mbpoll === | === mbpoll === | ||
+ | == PDFs == | ||
+ | [[Media:FoLinn_H1_Series_Inverter_User_Manual.pdf]] | ||
== Online Resources == | == Online Resources == | ||
− | [https://www. | + | [https://www.cncwiki.org/images/c/c1/FoLinn_H1_Series_Inverter_User_Manual.pdf H1 Series Inverter User Manual (2021.V1.0)] (StepperOnline, no FoLinn mentioned) |
+ | |||
+ | [https://www.omc-stepperonline.com/download/H1_Series_Inverter_Easy_User_Manual.pdf H1 Series Inverter Simple Manual] (StepperOnline, no FoLinn mentioned) | ||
− | [https://www.omc-stepperonline.com/ | + | [https://www.omc-stepperonline.com/index.php?route=product/product/get_file&file=3332/EV50_Series_Inverter_Full_User_Manual.pdf LinsVFD EV50 Series Inverter Full User Manual] (LinsVFD on StepperOnline, no FoLinn mentioned) |
+ | |||
+ | [https://www.omc-stepperonline.com/index.php?route=product/product/get_file&file=3332/EV50_Series_Inverter_Easy_User_Manual.pdf LinsVFD EV50 Series Inverter Easy User Manual] (LinsVFD on StepperOnline, no FoLinn mentioned) | ||
[https://www.chinafolinn.com/uploads/image/20201021/5f8f9c43a68b0.pdf H1 Series Inverter Simple Manual (2020.10.21)] (Folinn) | [https://www.chinafolinn.com/uploads/image/20201021/5f8f9c43a68b0.pdf H1 Series Inverter Simple Manual (2020.10.21)] (Folinn) | ||
Line 336: | Line 461: | ||
[https://www.chinafolinn.com/uploads/image/20200602/5ed61f05888f9.pdf H1 Series Compact Inverter Brochure (2020.06.02)] (Folinn) | [https://www.chinafolinn.com/uploads/image/20200602/5ed61f05888f9.pdf H1 Series Compact Inverter Brochure (2020.06.02)] (Folinn) | ||
− | https://cononmotor.com.au/wp-content/uploads/2022/05/2.29.182-H1-Detailed-Manual-%E8%8B%B1%E6%96%87%E7%89%88%E8%AF%A6%E7%BB%86%E8%AF%B4%E6%98%8E%E4%B9%A61.pdf | + | [https://cononmotor.com.au/wp-content/uploads/2022/05/2.29.182-H1-Detailed-Manual-%E8%8B%B1%E6%96%87%E7%89%88%E8%AF%A6%E7%BB%86%E8%AF%B4%E6%98%8E%E4%B9%A61.pdf 2.29.182-H1-Detailed-Manual-英文版详细说明书1.pdf] |
+ | |||
+ | [https://cononmotor.com.au/wp-content/uploads/2020/03/H1-Simple-User-Manual-Revised.pdf H1-Simple-User-Manual-Revised.pdf] | ||
− | https:// | + | [https://www.omc-stepperonline.com/linsvfd LinsVFD Variable Frequency Drives] (now LinsVFD branded instead of StepperOnline nor FoLinn?) |
[https://www.omc-stepperonline.com/h100-series-vfd-variable-frequency-drive H100 Series VFD Variable Frequency Drive] | [https://www.omc-stepperonline.com/h100-series-vfd-variable-frequency-drive H100 Series VFD Variable Frequency Drive] |
Latest revision as of 05:06, 22 May 2024
Overview
Variable frequency drives (VFDs) made by Fuling Electric, aka Folinn Electric. They are rebranded by StepperOnline.
Model Numbers
- Page 6 (7 in the PDF) shows the model number scheme
Wiring Diagram
- Page 7 (10 in the PDF) shows the power wiring
- Page 67 (129 in the PDF) shows the H0101 interface panel screw terminal / RJ45 pinout
- Page 68 (132 in the PDF) shows the H0110 interface panel screw terminal / RJ45 pinout
- Page 72 (139 in the PDF) shows the H0100 interface panel screw terminal pinout
- Page 73 (142 in the PDF) shows the H0200 interface panel screw / RJ45 / D-Sub? terminal pinout
- Page 76 (147 in the PDF) shows the H0201 interface panel screw / RJ45 / D-Sub? terminal pinout
NOTE: they claim that pins 1&2 on the RJ45 are RS-485+/-, but in reality it's reversed and pins 8&7 are RS-485+/- and pins 2&4 are GND.
Dimensions
- Page 65 (126 in the PDF) show a table of the dimensions
Parameters
Parameter No. | Default Value | Range | Description |
---|---|---|---|
P02.18 | 50.000 Hz | 0.000 - 99999.000 Hz | Maximum setting value |
P02.19 | 0.000 Hz | 0.000 - 99999.000 Hz | Minimum setting value |
P02.50 | 0.050 - 3600.000 s | Acceleration time 0 | |
P02.70 | 0.050 - 3600.000 s | Deceleration time 0 | |
P05.08 | 55.000 Hz | -1020.000 - 1020.000 Hz | Motor upper frequency limit |
P06.00 | 0: off 1: complete 2: simple |
Motor parameter self-learning | |
P06.10 | 0: asynchronous | 0: asynchronous 1: surface mount permanent magnet synchronous 2: salient pole permanent magnet synchronous 4: single-phase motor |
Motor type |
P06.05 | 2-16 kHz | Carrier frequency | |
P06.11 | 0.000 - 100000.000 kW | Motor rated power | |
P06.12 | 0 - 1000 V | Motor rated voltage | |
P06.13 | 1 - 3000 Hz | Motor rated frequency | |
P06.14 | 0.00 - 1000.00 A | Motor rated current | |
P06.15 | 10 - 65535 RPM | Motor rated speed | |
P06.16 | 0.00 - 1.00 (ratio) | Motor power factor | |
P06.17 | 2 - 100 poles (not pairs) | Motor pole count | |
P06.18 | 0.1 - 10000.0 Nm | Motor rated torque | |
P06.19 | 0.00 - 1000.00 A | Motor no-load current | |
P06.20 | 1.000 - 10000.000 mV/RPM | PM motor back EMF/rev | |
P06.40 | 0.000 - 99.990 ohms | Stator impedance | |
P06.41 | 0.000 - 99.990 ohms | Rotor impedance | |
P06.42 | 0.000 - 999.990 mH | Stator leakage reactance | |
P06.44 | 0.00 - 999.90 mH | Motor main reactance |
Modbus control
VFD Parameters
Parameter No. | Default Value | Required Value | Description |
---|---|---|---|
P01.40 | 1: RTU | 1: RTU | MODBUS communication protocol |
P01.41 | 1 | 1 | MODBUS slave address |
P01.42 | 3: 19,200 baud | 3: 19,200 baud | MODBUS baud-rate |
P01.43 | 0: none | 0: none | MODBUS parity check |
P01.44 | 8 | 8 | MODBUS data bits |
P01.45 | 1.0 | 1.0 | MODBUS stop bits |
P01.46 | 3 | 3 | MODBUS communication delay time |
P01.47 | 0 | 0 | MODBUS parameter decimal mode |
P02.10 | 0: keyboard | 5: communication | Set value source 1 |
P02.90 | Communication set value | ||
P02.91 | Communication command | ||
P03.00 | 1: keyboard | 2: communication | Start command source |
P03.01 | 0: no effect | 2: communication (?) | Reverse start command source |
P03.02 | 0: no effect | 2: communication (?) | Reverse command source |
P03.03 | 1: keyboard | 2: communication (?) | Jog command source |
P03.04 | 0: no effect | 2: communication (?) | Stop command source |
P03.05 | 0: no effect | 2: communication (?) | Free parking command source |
P03.06 | 0: no effect | 2: communication (?) | Safe stop command source |
P03.07 | 1: keyboard | 2: communication (?) | Reset command source |
P03.08 | 0: no effect | 2: communication (?) | Fault command source |
P03.09 | 0: no effect | 2: communication (?) | Pause command source |
Modbus registers
Parameter No. | 16-bit Register No. | Value | R/W | Description |
---|---|---|---|---|
P01.47 | 0x0092? | 0 - 123 | Parameter decimal mode | |
P02.18 | 0x00d9? | 0.0 - 99999.000 | Maximum set value | |
P02.90 | 0x0121 | W | Communication set value | |
P02.91 | 0x0122 | W | Communication commands | |
P10.05 | 0x03EC? | Software version number | ||
P10.10 | 0x03F1? | 0x0 - 0xFFFFFFFF | Control word | |
P10.11 | 0x03F2? | -65535.0 - 65535.0 Hz | Set value | |
P10.15 | 0x03F6 | 0x0 - 0xFFFFFFFF | R | Current state |
P10.16 | 0x03F7 | 0x0 - 0xFFFFFFFF | R | Fault state word 1 |
P10.17 | 0x03F8? | 0x0 - 0xFFFFFFFF | Fault state word 2 | |
P10.18 | 0x03F9? | 0x0 - 0xFFFFFFFF | Alarm state word | |
P10.20 | 0x03FB? | 0.0 - 65535.0 Hz | Output frequency absolute value | |
P10.21 | 0x03FC | -65535.0 - 65535.0 Hz | R | Output frequency |
P10.22 | 0x03FD | 0.00 - 65535.00 A | R | Output current |
P10.23 | 0x03FE | 0.0 - 65535.0 V | R | Output voltage |
P10.24 | 0x03FF | 0.000 - 65535.000 Nm | R | Output torque |
P10.25 | 0x0400 | 0.0 - 65535.0 V | R | DC voltage |
P10.26 | 0x0401 | 0 - 65535 C | R | Inverter temperature |
P10.27 | 0x0402? | 0 - 65535 % | Inverter hot load | |
P10.28 | 0x0403? | 0 - 65535 % | Motor hot load | |
P10.30 | 0x0405 | 0.000 - 65535.000 kW | R | Power |
P10.31 | 0x0406 | 0.000 - 4294967.295 kWh | R | Energy consumption |
P10.40 | 0x040F | 0.000 - 4294967.295 h | R | Hours of power on |
P10.41 | 0x041F | 0 - (2^32-1) | R | Number of power-on |
P10.60 | 0x0423? | 0 - (2^32-1) | Current alarm number | |
P10.90 | 0x0441 | -999999.000 - 999999.000 % | Set value 1 |
NOTE: you add 0x4000 (16,384) to the addresses to go from 16-bit mode to 32-bit mode
NOTE: you add 0x8000 (32,768) to the addresses to go from EEPROM to RAM access (important when writing frequently over MODBUS!)
mbpoll
PDFs
Media:FoLinn_H1_Series_Inverter_User_Manual.pdf
Online Resources
H1 Series Inverter User Manual (2021.V1.0) (StepperOnline, no FoLinn mentioned)
H1 Series Inverter Simple Manual (StepperOnline, no FoLinn mentioned)
LinsVFD EV50 Series Inverter Full User Manual (LinsVFD on StepperOnline, no FoLinn mentioned)
LinsVFD EV50 Series Inverter Easy User Manual (LinsVFD on StepperOnline, no FoLinn mentioned)
H1 Series Inverter Simple Manual (2020.10.21) (Folinn)
H1 Series Compact Inverter Brochure (2020.06.02) (Folinn)
2.29.182-H1-Detailed-Manual-英文版详细说明书1.pdf
H1-Simple-User-Manual-Revised.pdf
LinsVFD Variable Frequency Drives (now LinsVFD branded instead of StepperOnline nor FoLinn?)
H100 Series VFD Variable Frequency Drive
H110 Series VFD Variable Frequency Drive
H1 Three Phase Archives | Conon Motor
H1 Three Phase Archives | Conon Motor
H1 Series Compact Vector Inverter- Zhejiang New Folinn Electric Co., Ltd