Difference between revisions of "Fuling DZB312 Series VFDs"
(updated setting speed) |
(added more PDF links) |
||
(2 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
== Model Numbers == | == Model Numbers == | ||
+ | |||
+ | In the DZB312 series manual: | ||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | ||
+ | |||
+ | In the DZB300 series manual: | ||
+ | |||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=7 Page 7] (marked 7 in the PDF) shows the model number scheme | ||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8] (marked 9 in the PDF) shows a table of model numbers and recommended component sizing | ||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=47 Page 47] (marked 88 in the PDF) shows the specifications based off the model number ranges | ||
== Wiring Diagram == | == Wiring Diagram == | ||
+ | |||
+ | In the DZB312 series manual: | ||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF) | ||
+ | |||
+ | In the DZB300 series manual: | ||
+ | |||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8-9] (marked 10-11 in the PDF) shows an overview of the wiring | ||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=9 Page 9] (marked 12 in the PDF) shows a the power terminal pinout | ||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=10 Page 10] (marked 13 in the PDF) shows a the control terminal pinout | ||
== Dimensions == | == Dimensions == | ||
+ | |||
+ | In the DZB312 series manual: | ||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | ||
− | == | + | In the DZB300 series manual: |
+ | |||
+ | * https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=55 Page 55] (marked 104 in the PDF) | ||
+ | |||
+ | == Parameters == | ||
+ | |||
+ | In the DZB312 series manual: | ||
+ | |||
+ | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (marked 18 in the PDF) shows the list of parameters | ||
+ | |||
+ | In the DZB300 series manual: | ||
+ | |||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=15 Page 15] (marked 23 in the PDF) shows the list of parameters | ||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=21 Page 21] (marked 36 in the PDF) shows the detailed description of the parameters | ||
− | == | + | == Fault Codes == |
In the DZB312 series manual: | In the DZB312 series manual: | ||
− | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page= | + | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=16 Page 16] (marked 29 in the PDF) shows a list of fault codes |
+ | |||
+ | In the DZB300 series manual: | ||
+ | |||
+ | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=43 Page 43] (marked 79 in the PDF) has a flowchart for diagnosing issues | ||
+ | |||
+ | == Modbus control == | ||
− | + | === VFD parameters === | |
+ | |||
+ | Parameters relevant for Modbus control: | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 139: | Line 178: | ||
| 0x2000 | | 0x2000 | ||
| 8192 | | 8192 | ||
− | | R/W | + | | R/W |
| -10000 - +100000 (frequency/PID percentage * 100) | | -10000 - +100000 (frequency/PID percentage * 100) | ||
− | | frequency/PID setpoint percentage | + | | frequency/PID setpoint percentage |
|- | |- | ||
| 0x3000 | | 0x3000 | ||
Line 170: | Line 209: | ||
| 12292 | | 12292 | ||
| R | | R | ||
− | | | + | | (rpm using parameter F1.03) |
| output speed | | output speed | ||
|- | |- | ||
Line 182: | Line 221: | ||
| 12294 | | 12294 | ||
| R | | R | ||
− | | | + | | ??? |
| output torque | | output torque | ||
|- | |- | ||
Line 218: | Line 257: | ||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2 | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2 | ||
− | # set the output frequency/PID percentage (percentage * 100) | + | # set the output frequency/rpm/PID percentage (percentage * 100) |
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000 | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000 | ||
Line 238: | Line 277: | ||
# monitor output voltage | # monitor output voltage | ||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003 | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003 | ||
+ | |||
+ | # monitor output rpm | ||
+ | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3004 | ||
# monitor inverter fault | # monitor inverter fault | ||
Line 248: | Line 290: | ||
[[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?) | [[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?) | ||
+ | |||
+ | [[Media:Fuling_DZB300_Series_Inverter_User_Manual.pdf]] | ||
== Online Resources == | == Online Resources == |
Latest revision as of 21:05, 18 March 2024
Overview
Variable frequency drives specialized for CNC router spindles. The drives are made by Fuling Electric, aka Folinn Electric.
Model Numbers
In the DZB312 series manual:
- Page 18 (marked 33 in the PDF)
In the DZB300 series manual:
- Page 7 (marked 7 in the PDF) shows the model number scheme
- Page 8 (marked 9 in the PDF) shows a table of model numbers and recommended component sizing
- Page 47 (marked 88 in the PDF) shows the specifications based off the model number ranges
Wiring Diagram
In the DZB312 series manual:
- Page 5 (marked 7 in the PDF)
In the DZB300 series manual:
- Page 8-9 (marked 10-11 in the PDF) shows an overview of the wiring
- Page 9 (marked 12 in the PDF) shows a the power terminal pinout
- Page 10 (marked 13 in the PDF) shows a the control terminal pinout
Dimensions
In the DZB312 series manual:
- Page 18 (marked 33 in the PDF)
In the DZB300 series manual:
- https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=55 Page 55] (marked 104 in the PDF)
Parameters
In the DZB312 series manual:
- Page 10 (marked 18 in the PDF) shows the list of parameters
In the DZB300 series manual:
- Page 15 (marked 23 in the PDF) shows the list of parameters
- Page 21 (marked 36 in the PDF) shows the detailed description of the parameters
Fault Codes
In the DZB312 series manual:
- Page 16 (marked 29 in the PDF) shows a list of fault codes
In the DZB300 series manual:
- Page 43 (marked 79 in the PDF) has a flowchart for diagnosing issues
Modbus control
VFD parameters
Parameters relevant for Modbus control:
Function Code | Serial No. | Default Value | Required Value | Description |
---|---|---|---|---|
F0.01 | 1 | 1: terminal | 2: RS-485 | run command source |
F0.03 | 3 | 1: AVI | 6: RS-485 | frequency command source |
F3.03 | 81 | 0: only keypad | 2: keypad and RS-485 | stop function sources |
F4.11 | 108 | 0 | ? | fault automatic reset number |
F4.18 | 115 | 0: keypad (F4.19) | 3: RS-485 | PID setpoint source |
F4.20 | 117 | 0: reserved | 3: RS-485 | PID feedback source |
F6.00 | 142 | 1 | RS-485 Modbus slave address | |
F6.01 | 143 | 3: 9,600 bps | RS-485 Modbus baudrate | |
F6.02 | 144 | 0: N, 8, 1 | RS-485 Modbus parity/data-width/stop-bits | |
F6.03 | 145 | 5 | RS-485 Modbus response delay (ms) | |
F6.04 | 146 | 0.0 (invalid) | 2.0 (2 seconds) | RS-485 Modbus timeout (s) |
F6.05 | 147 | 1: continue without alarm | 2: stop with alarm (only when in RS-485 mode) | RS-485 Modbus error handling |
F6.06 | 148 | 0: respond to writes | 0: respond to writes | RS-485 Modbus write response |
Modbus registers
In the DZB300 series manual (which also applies to DZB312 series):
- Page 49 (91 in the PDF) describes the Modbus protocol (should be standards compliant)
- Page 53 (100 in the PDF) has the register address map
Register No. (hex) | Register No. (dec) | R/W | Value | Description |
---|---|---|---|---|
0x1000 | 4096 | R/W | 1-8 (look in manual) | Modbus controlled command |
0x1001 | 4097 | R | 1-4 | inverter state |
0x2000 | 8192 | R/W | -10000 - +100000 (frequency/PID percentage * 100) | frequency/PID setpoint percentage |
0x3000 | 12288 | R | (decimal Hz * 10) | frequency setpoint |
0x3001 | 12289 | R | (decimal Hz * 10) | output frequency |
0x3002 | 12290 | R | ??? | output current |
0x3003 | 12291 | R | (decimal V) | output voltage |
0x3004 | 12292 | R | (rpm using parameter F1.03) | output speed |
0x3005 | 12293 | R | ??? | output power |
0x3006 | 12294 | R | ??? | output torque |
0x3007 | 12295 | R | (decimal V * 10) | DC bus voltage |
0x5000 | 20480 | R | ??? | inverter fault address |
0x5001 | 20481 | R | 0-8 (look in manual) | Modbus communication fault |
mbpoll
# fault reset (need to test) ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 7 # stop ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 5 # set forward run ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 1 # set reverse run ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2 # set the output frequency/rpm/PID percentage (percentage * 100) ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000 # monitor command (whatever was previously written, can be invalid) ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 # monitor inverter status ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1001 # monitor commanded frequency ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3000 # monitor output frequency ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3001 # monitor output current ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3002 # monitor output voltage ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003 # monitor output rpm ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3004 # monitor inverter fault ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x5000 # monitor Modbus communication fault ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x5001
PDFs
Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf (not available online?)
Media:Fuling_DZB300_Series_Inverter_User_Manual.pdf
Online Resources
DZB312 Series Engraving Machine Special Inverter_ZHEJIANG NEW FOLINN ELECTRIC CO.,LTD
DZB312变频器-DZB312系列雕刻机专用变频器-浙江新富凌电气股份有限公司 (Chinese version of above link)
DZB300 Series General Vector Inverter_ZHEJIANG NEW FOLINN ELECTRIC CO.,LTD
DZB300变频器-DZB300系列通用矢量型变频器-浙江新富凌电气股份有限公司 (Chinese version of above link)
http://www.chinafuling.com/uploads/image/20200602/5ed609046fdd7.pdf (DZB312 series manual in Chinese)
http://www.chinafolinn.com/uploads/image/20200602/5ed6233f8b4eb.pdf (DZB300 series manual in English)
http://www.chinafuling.com/uploads/image/20200602/5ed6078d6dfde.pdf (DZB300 series manual in Chinese)
Home_ZHEJIANG NEW FOLINN ELECTRIC CO.,LTD (English website)
富凌官网-变频器-伺服驱动-主轴电机-全国统一服务热线:400-889-7111 (Chinese website)